1. Working voltage: DC 4~30V;
2. Working current: less than 133μA
3. Output voltage: +6V~-1.0V
4. Output impedance: 0.1Ω at 1mA load;
5. Accuracy: 0.5°C accuracy (at +25°C);
6. Leakage current: less than 60μA;
7. Scaling factor: linear +10.0mV/℃;
8. Non-linear value: ±1/4℃;
9. Calibration method: directly calibrate with Celsius temperature;
10. Rated operating temperature range: -55~+150℃.
11. Pin description: ①power supply negative GND; ②power supply positive VCC; ③signal output S;